RIFT J. Head, Ed. Internet-Draft T. Przygienda Intended status: Standards Track C. Barth Expires: 11 January 2024 Juniper Networks 10 July 2023 RIFT Auto-Flood Reflection draft-head-rift-auto-fr-03 Abstract This document specifies procedures where RIFT can automatically provision IS-IS Flood Reflection topologies by leveraging its native no-touch ZTP architecture. Status of This Memo This Internet-Draft is submitted in full conformance with the provisions of BCP 78 and BCP 79. Internet-Drafts are working documents of the Internet Engineering Task Force (IETF). Note that other groups may also distribute working documents as Internet-Drafts. The list of current Internet- Drafts is at https://datatracker.ietf.org/drafts/current/. Internet-Drafts are draft documents valid for a maximum of six months and may be updated, replaced, or obsoleted by other documents at any time. It is inappropriate to use Internet-Drafts as reference material or to cite them other than as "work in progress." This Internet-Draft will expire on 11 January 2024. Copyright Notice Copyright (c) 2023 IETF Trust and the persons identified as the document authors. All rights reserved. This document is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (https://trustee.ietf.org/ license-info) in effect on the date of publication of this document. Please review these documents carefully, as they describe your rights and restrictions with respect to this document. Code Components extracted from this document must include Revised BSD License text as described in Section 4.e of the Trust Legal Provisions and are provided without warranty as described in the Revised BSD License. Head, et al. Expires 11 January 2024 [Page 1] Internet-Draft RIFT Auto-FR July 2023 Table of Contents 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1. Requirements Language . . . . . . . . . . . . . . . . . . 3 2. Design Considerations . . . . . . . . . . . . . . . . . . . . 3 3. Auto-FR Device Roles . . . . . . . . . . . . . . . . . . . . 4 3.1. All Participating Nodes . . . . . . . . . . . . . . . . . 4 3.2. Flood Reflectors . . . . . . . . . . . . . . . . . . . . 4 3.3. Flood Reflector Spines . . . . . . . . . . . . . . . . . 5 3.4. Flood Reflectors Clients . . . . . . . . . . . . . . . . 5 4. Auto-FR Variable Derivation . . . . . . . . . . . . . . . . . 5 4.1. RIFT System ID . . . . . . . . . . . . . . . . . . . . . 5 4.2. Auto-FR Version . . . . . . . . . . . . . . . . . . . . . 6 4.3. Flood Reflection Cluster ID . . . . . . . . . . . . . . . 6 4.4. Flood Reflection Preference . . . . . . . . . . . . . . . 6 4.5. IS-IS System ID . . . . . . . . . . . . . . . . . . . . . 7 4.6. IS-IS NET Address . . . . . . . . . . . . . . . . . . . . 7 4.7. Loopback Address . . . . . . . . . . . . . . . . . . . . 7 4.7.1. Leaf Nodes as Flood Reflector Clients . . . . . . . . 7 4.7.2. ToF Nodes as Flood Reflectors . . . . . . . . . . . . 8 4.7.2.1. Flood Reflector Election Procedures . . . . . . . 8 5. RIFT Requirements . . . . . . . . . . . . . . . . . . . . . . 9 5.1. RIFT FSM / LIE Validation Requirements . . . . . . . . . 9 5.2. RIFT Node-TIE Advertisements . . . . . . . . . . . . . . 9 6. Operational Considerations . . . . . . . . . . . . . . . . . 9 6.1. RIFT Underlay and IS-IS Flood Reflection Topology . . . . 9 6.2. Auto-FR Analytics . . . . . . . . . . . . . . . . . . . . 11 6.2.1. Auto-FR Analytics (Global) Key/Value Pair . . . . . . 12 7. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 13 8. Security Considerations . . . . . . . . . . . . . . . . . . . 14 9. Acknowledgements . . . . . . . . . . . . . . . . . . . . . . 14 10. References . . . . . . . . . . . . . . . . . . . . . . . . . 14 10.1. Normative References . . . . . . . . . . . . . . . . . . 14 Appendix A. YANG Model . . . . . . . . . . . . . . . . . . . . . 14 Appendix B. Thrift Models . . . . . . . . . . . . . . . . . . . 14 B.1. common.thrift . . . . . . . . . . . . . . . . . . . . . . 15 B.2. encoding.thrift . . . . . . . . . . . . . . . . . . . . . 15 B.3. common_flood_reflection.thrift . . . . . . . . . . . . . 16 Appendix C. auto_flood_reflection_kv.thrift . . . . . . . . . . 18 Appendix D. Auto-FR Variable Derivation . . . . . . . . . . . . 20 Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . 25 Head, et al. Expires 11 January 2024 [Page 2] Internet-Draft RIFT Auto-FR July 2023 1. Introduction [RIFT] is a protocol that focuses heavily on operational simplicity. It natively supports Zero Touch Provisioning (ZTP) functionality that allows each node to automatically derive its place in the topology and configure itself accordingly when properly cabled as a Clos, Fat- Tree, or other similarly structured variant. IS-IS Flood Reflection [RFC9377] is a mechanism that enables flat single-area Level 2 IS-IS topologies to scale well beyond their typical properties when deployed in similar topological structures by: 1. Reducing the number of required links and adjacencies. 2. Reducing the size of the Link-State Database. 3. Reducing the amount of flooding. 4. Reducing the number of SPF computations. 5. Reducing the maximum SPF computation time. RIFT Auto-Flood Reflection (Auto-FR) combines these technologies by using RIFT's ZTP functionality in order to automatically provision IS-IS Flood Reflection topologies in a completely distributed fashion. 1.1. Requirements Language The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in RFC 2119 [RFC2119]. 2. Design Considerations IS-IS Flood Reflection operates using Flood Reflectors at the top of the fabric and Flood Reflector Clients at the bottom of the fabric. Any nodes in the middle are not required to support Flood Reflection functionality, nor do they need to support Auto-FR. Nodes in a Flood Reflection topology require specific variables for deployment. For example, a Cluster ID that is unique to the particular fabric or loopback addresses that are unique to a particular node. RIFT has enough topological information to derive these variables with the appropriate scope in a distributed fashion automatically. Head, et al. Expires 11 January 2024 [Page 3] Internet-Draft RIFT Auto-FR July 2023 Once the Flood Reflection topology is built, RIFT Key-Value TIEs can be used to distribute operational state information to allow for cluster-wide validation without any additional tooling. 3. Auto-FR Device Roles Auto-FR requires that each node understands its given role within the scope of the Flood Reflection deployment, so each node derives the necessary variables and resulting configuration. 3.1. All Participating Nodes Not all nodes have to participate in Auto-FR, however, if a node does assume an Auto-FR role, it MUST be capable of deriving the following variables: *Flood Reflection Cluster ID* The Flood Reflection Cluster ID us to distinguish reflection domains (similar to the Cluster ID use in BGP Route Reflection). *IPv6 Loopback Address* Unique IPv6 loopback address. *IS-IS System ID* The IS-IS System Identifier used in deriving the IS-IS NET Address. *IS-IS NET Address* The IS-IS NET Address used to uniquely identify an IS-IS node. 3.2. Flood Reflectors This section defines an Auto-FR role whereby some ToF (Top-of-Fabric) nodes act as IS-IS Flood Reflectors. It is expected that Flood Reflectors will establish Level 2 IS-IS adjacencies with Flood Reflector Clients in the same area, in the same fabric. The typical Flood Reflector requirements do not change, however, determining which specific values to use requires further consideration. ToF nodes performing Flood Reflector functionality MUST derive the following variables: *IPv6 Flood Reflector Loopback Address* Unique IPv6 loopback address. Head, et al. Expires 11 January 2024 [Page 4] Internet-Draft RIFT Auto-FR July 2023 3.3. Flood Reflector Spines In the context of Auto-FR, a "spine" can simply be desribed as an Auto-FR node not running as a Flood Reflector (ToF) or Flood Reflector Client (leaf). While RIFT Auto-FR is not required to run on spine nodes and as such a spine role has no specific variables to derive at this time, it may be desirable to do so to facilitate the use of Auto-FR specific Key-Value TIEs. This section also serves as a placeholder for future considerations and enhancements. *Future Consideration* Future Consideration 3.4. Flood Reflectors Clients Although no specific variables for Flood Reflector Clients are described at this time, the generic role is specified as a placeholder for future enhancements. *Future Consideration* Future Consideration 4. Auto-FR Variable Derivation As previously mentioned, not all nodes are required to derive all variables in a network. For example, spine nodes may only be required for transit traffic and not need to support Auto-FR at all. All variables are derived from RIFT's FSM or ZTP mechanism, so no additional flooding other than RIFT's typical flooding is required. It is also important to mention that all variable derivation is in some way based on the RIFT System ID and/or Cluster ID and MUST comply precisely with calculation methods specified in the Auto-FR Variable Derivation section to allow interoperability between different implementations. All necessary foundational code elements are also mentioned there. 4.1. RIFT System ID The 64-bit RIFT System ID that uniquely identifies a node as defined in RIFT [RIFT]. This not derived specifically for Auto-FR, but for all RIFT nodes and is used in the derivation procedures described in this section. Head, et al. Expires 11 January 2024 [Page 5] Internet-Draft RIFT Auto-FR July 2023 4.2. Auto-FR Version This section describes extensions to both the RIFT LIE and Node-TIE packet schemas in the form of a 16-bit value that identifies the Auto-FR Version. Auto-FR capable nodes MUST support this extension, but MAY choose not to advertise it in LIEs and Node-TIEs when Auto-FR is not being utilized. The complete encoding.thrift schema documented in RIFT [RIFT] describes both major and minor protocol/schema versions. Auto-FR Version calculation is done by multiiplying a static value of 256 by the major version then adding the minor version, that is to say - 256 * MAJOR + MINOR. This section also describes an extension to the NodeCapabilities schema indicating whether or not a node supports Auto-FR. The appendix (Appendix B) details necessary changes to the LIEPacket, NodeTIEElement, and NodeCapabilities Thrift schemas. 4.3. Flood Reflection Cluster ID This section describes extensions to both the RIFT LIE and Node-TIE packet schemas in the form of a 32-bit value that identifies the Auto-FR Cluster ID. Auto-FR capable nodes MUST support this extension, but MAY choose not to advertise it in LIEs and Node-TIEs when Auto-FR is not being utilized. Deployments using more than one Auto-FR cluster MUST use different Cluster IDs. Failure to do so may cause sub-optimal routing as L1/L2 nodes from different clusters would belong to the same subnet. A Cluster ID with a value of 0 is considered invalid and MUST NOT be used for any purpose. The appendix (Appendix B) details necessary changes to the LIEPacket and NodeTIEElement Thrift schemas. 4.4. Flood Reflection Preference This section describes extensions to the Node-TIE packet schema in the form of a 32-bit value that indicates a Flood Reflection Preference value to be used during Flood Reflector election procedures with the higher value being preferred. Auto-FR capable nodes MUST support this extension. The appendix (Appendix B) details necessary changes to the NodeTIEElement Thrift schemas. Head, et al. Expires 11 January 2024 [Page 6] Internet-Draft RIFT Auto-FR July 2023 4.5. IS-IS System ID Auto-FR nodes MUST derive a unique 8-byte IS-IS System ID for use in deriving the IS-IS NET Address. Calculation is done using the 8-byte RIFT System ID and 4-byte Cluster ID. In order for nodes to derive an IS-IS System ID, the following algorithms are required - auto_fr_cidsid2isissid (Figure 11) and auto_fr_v6hash (Figure 16). 4.6. IS-IS NET Address Auto-FR nodes MUST derive a unique 10-byte IS-IS NET (Network Entity Title) Address to uniquely identify itself within the Flood Reflection topology. The 1st byte (which indicates the AFI) MUST have a value of "49". The last byte (i.e. the NSEL) MUST have a value of 0. Remaining calculation is done using the 8-byte RIFT System ID and 4-byte Cluster ID. In order for nodes to derive an IS-IS NET Address, the following algorithms are required - auto_fr_cidsid2isisnet (Figure 10) and auto_fr_cidsid2isissid (Figure 11). 4.7. Loopback Address Auto-FR nodes MUST derive a ULA-scoped IPv6 loopback address to be used in IS-IS. Calculation is done using the 6-bytes of reserved ULA space, the 4-byte Cluster ID, and the node's 8-byte RIFT System ID. Derivation of the IS-IS System ID varies slightly depending upon the node's location/role in the fabric and will be described in subsequent sections. 4.7.1. Leaf Nodes as Flood Reflector Clients Leaf Nodes acting as Flood Reflector Clients MUST derive their loopback address according to the specific section describing the algorithm. Calculation is done using the 6-bytes of reserved ULA space, the 4-byte Cluster ID, and the 8-byte RIFT System ID. In order for leaf nodes to derive IPv6 loopbacks, the following algorithms are required - auto_fr_cidsidv6loopback (Figure 13) and auto_fr_v6prefixcidsid2loopback (Figure 17). IPv4 addresses MAY be supported, but it should be noted that they have a higher likelihood of collision. The appendix contains the required auto_fr_cidsid2v4loopback (Figure 12) algorithm to support IPv4 loopback derivation. Head, et al. Expires 11 January 2024 [Page 7] Internet-Draft RIFT Auto-FR July 2023 4.7.2. ToF Nodes as Flood Reflectors ToF nodes acting as Flood Reflectors MUST derive their loopback address according to the specific section describing the algorithm. Calculation is done using the 6-bytes of reserved ULA space, the 4-byte Cluster ID, and the 8-byte RIFT System ID. In order for ToF nodes to derive IPv6 loopbacks, the following algorithms are required - auto_fr_cidsidv6loopback (Figure 13), auto_fr_v6prefixcidsid2loopback (Figure 17), and auto_fr_cidfrpref2frv6loopback (Figure 9). IPv4 addresses MAY be supported, but it should be noted that they have a higher likelihood of collision. The appendix contains the required auto_fr_cidfrpref2frv4loopback (Figure 8) algorithm to support IPv4 loopback derivation. 4.7.2.1. Flood Reflector Election Procedures Each ToF performs the election independently based on the RIFT System IDs and a Flood Reflection preference value of other ToF nodes in the fabric obtained via southbound reflection. The Flood Reflector election procedures are defined as follows: 1. Highest System ID with the highest preference. 2. Lowest System ID with the highest preference. 3. 2nd highest System ID with the 2nd highest preference. 4. etc. This ordering is necessary to prevent a single node with either the highest or lowest System ID from triggering changes to flood reflector loopback addresses as it would result in all IS-IS adjacencies flapping. For example, if ToF01 (System ID: 002c6af5a281c000 / FR Preference: 100) and ToF02 (System ID: 002c6bf5788fc000 / FR Preference: 1) went through the election process, ToF02 would be elected due to it having the highest System ID. If a ToF determines that it is elected as a Flood Reflector, it uses the knowledge of its position in the list to derive Flood Reflector IPv6 loopback address. Head, et al. Expires 11 January 2024 [Page 8] Internet-Draft RIFT Auto-FR July 2023 A topology MUST elect at least 1 ToF node as an IS-IS Flood Reflector, but SHOULD elect 3. The election process varies depending upon whether or not the topology is comprised of a single plane or multiple planes. The multiplane election procedure will be described in a future version of this document. The algorithm shown in "auto_fr_sids2frs" (Figure 14) is required to perform the Flood Reflector election procedures. 5. RIFT Requirements 5.1. RIFT FSM / LIE Validation Requirements RIFT FSM adjacency rules MUST consider Auto-FR Version (Section 4.2) and Auto-FR Cluster ID (Section 4.3) values so that nodes that do not support Auto-FR can interoperate with nodes that do. The LIE validation is extended with the following clause and if it is not met, miscabling should be declared: (if auto_flood_reflection_version is not advertised by either node OR if auto_flood_reflection_version is identical on both nodes) AND (auto_flood_reflection_cluster_id is not advertised by either node OR auto_flood_reflection_cluster_id is identical on both nodes) 5.2. RIFT Node-TIE Advertisements All nodes utilizing Auto-FR MUST advertise their Auto-FR Version (Section 4.2), Flood Reflection Cluster ID (Section 4.3), and Flood Reflection Preference (Section 4.4) values in at least one Node-TIE in each direction (i.e. North and South). 6. Operational Considerations To fully realize the benefits of Auto-FR, it may help to describe the high-level method. Simply put, RIFT automatically provisions the underlay and Auto-FR provisions the Flood Reflection topology. The goal of this section is to draw simple lines between general fabric concepts, RIFT, and Auto-FR and how they fit into current network designs and practices. This section also describes a set of optional Key-Value TIEs [RIFT-KV] that leverages the variables that have already been derived to provide further operational enhancement to the operator. 6.1. RIFT Underlay and IS-IS Flood Reflection Topology Head, et al. Expires 11 January 2024 [Page 9] Internet-Draft RIFT Auto-FR July 2023 +-----------------+ +-----------------+ | ToF-01 | | ToF-02 | | L1 / L2 | | L1 / L2 | ]----------------------+ | Flood Reflector | | Flood Reflector | | +-+--+------+--+--+ +-+--+------+--+--+ | | | | | | | | | | +---------------------+ | | | | | | | | | | | | | | | +---------------------+ | | +-----------)------)--)--------+ | | | | | | | | | +-------+ | | | | | | | | | | | | | | | | +---)--------------)-----------+ | | | | | | | | | | | | | +--+ +------)----+ +--+ | | | | | | | | | | | | | | | +---+ | | | | | Level 2 Mesh of | | | | | | | | | Flood Reflection +-+------------+-+ +-+------------+-+ +-+------------+-+ +-+------------+-+ | Adjacencies | Spine-1-1 | | Spine-1-2 | | Spine-2-1 | | Spine-2-2 | | Between ToFs/Leafs | L1 | | L1 | | L1 | | L1 | | | N/A | | N/A | | N/A | | N/A | | +--+----------+--+ +--+----------+--+ +--+----------+--+ +--+----------+--+ | | | | | | | | | | | +----------)---+ | | +----------)---+ | | | | | | | | | | | | +----------+ | | | +----------+ | | | | | | | | | | | | +--+----------+--+ +------+------+--+ +--+----------+--+ +------+------+--+ | | Leaf-1-1 | | Leaf-1-2 | | Leaf-2-1 | | Leaf-2-2 | | | L1 / L2 | | L1 / L2 | | L1 / L2 | | L1 / L2 | ]-+ | FR Client | | FR Client | | FR Client | | FR Client | +--+-------------+ +--------------+-+ +--+-------------+ +----------------+ | | | | | | | | +--+-------------+ +--+-----------+-+ | Node A | | Node Z | | L2 | | L2 | +----------------+ +----------------+ Figure 1: Auto-FR Example Topology Figure 1 illustrates a typical 5-stage Clos IP fabric. Each node is named and labelled in such a way that conveys: 1. The node's generic placement within the context of the RIFT underlay Head, et al. Expires 11 January 2024 [Page 10] Internet-Draft RIFT Auto-FR July 2023 2. The node's level(s) within the IS-IS area. 3. The node's role within the IS-IS Flood Reflection topology. Table 1 should help further align these concepts. +================+=============+========================+ | RIFT Placement | IS-IS Level | IS-IS FR Role | +================+=============+========================+ | ToF Nodes | L1/L2 | Flood Reflector | +----------------+-------------+------------------------+ | Spine Nodes | L1 | N/A | +----------------+-------------+------------------------+ | Leaf Nodes | L1/L2 | Flood Reflector Client | +----------------+-------------+------------------------+ Table 1: Role Associations Connections between various nodes can be understood in two different ways: 1. Lines between ToF and leaf nodes are Level 2 IS-IS Flood Reflection adjacencies. 2. Lines between spine and leaf are part of the physically connected underlay. 3. Lines between ToF and spine are part of the physically connected underlay. It is important to remember that Auto-FR is not altering the way in which IS-IS Flood Reflection operates in any way, it simply takes existing deployment scenarios and simplifies the provisioning process. 6.2. Auto-FR Analytics Leaf nodes MAY optionally advertise analytics information about the Auto-FR fabric to ToF nodes using RIFT Key-Value TIEs [RIFT-KV]. This may be helpful in that validation and troubleshooting activities can be performed on the ToF nodes rather than manually verifying the state separately on multiple leaf nodes. Head, et al. Expires 11 January 2024 [Page 11] Internet-Draft RIFT Auto-FR July 2023 6.2.1. Auto-FR Analytics (Global) Key/Value Pair This Key/Value pair describes node level information within the context of the Flood Reflection topology. The RIFT System ID of the advertising leaf node MUST be used to differentiate the node among other nodes in the fabric. The Auto-FR Analytics (Global) Key/Value pair MUST be advertised with the 3rd and 4th bytes of the Key Identifier consisting of all 0s. 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Well-Known | Auto-FR Analytics (Global) | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | (Auto-FR Role, | | Flood Reflection Cluster ID, | | Established IS-IS FR L2 Adjacencies, | | Total IS-IS FR L2 Adjacencies, | | Established IS-IS FR L1 Shortcut Adjacencies, | | Total IS-IS FR L1 Shortcut Adjacencies, | | Established IS-IS L1 Adjacencies, | | Total IS-IS L1 Adjacencies,) | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ Figure 2: Auto-FR Global Key/Value Pair *where:* *Auto-FR Role:* A REQUIRED value indicating the node's Auto-FR role within the fabric. *0:* Illegal value, MUST NOT be used. *1:* Auto-FR Flood Reflector Client *2:* Auto-FR Flood Reflector *3:* Auto-FR Spine (i.e. a non-ToF / non-Leaf node) *Auto-FR Cluster ID* A REQUIRED 32-bit integer indicating the Auto-FR Cluster ID of the local node. Head, et al. Expires 11 January 2024 [Page 12] Internet-Draft RIFT Auto-FR July 2023 *Established IS-IS Flood Reflector Adjacency Count* A RECOMMENDED 16-bit integer indicating the number of IS-IS Level 2 Flood Reflector adjacencies in the "Up" state on the local node. *Total IS-IS Flood Reflector Adjacency Count* A RECOMMENDED 16-bit integer indicating the total number of IS- IS Level 2 Flood Reflector adjacencies on the local node regardless of state. *Established IS-IS Level 1 Shortcut Count* A RECOMMENDED 16-bit integer indicating the number of functional IS-IS Level 1 "shortcuts" on the local node. *Total IS-IS Level 1 Shortcut Count* A RECOMMENDED 16-bit integer indicating the total number of IS- IS Level 1 "shortcuts" the local node regardless of state. *Established IS-IS Level 1 Adjacency Count* A RECOMMENDED 16-bit integer indicating the number of IS-IS Level 1 adjacencies in the "Up" state on the local node. *Total IS-IS Level 1 Adjacency Count* A RECOMMENDED 16-bit integer indicating the total number of IS- IS Level 1 adjacencies on the local node regardless of state. Implementations leveraging Thrift for Key-Value functionality SHOULD refer to the auto_flood_reflection_kv.thrift (Appendix C) schema in the appendix. 7. IANA Considerations This section requests the following suggested values from the RIFT Well-Known Key-Type Registry. +=======+================+==============================+===========+ | Value | Key-Identifier | Description | Status/ | | | | | Reference | +=======+================+==============================+===========+ | 5 | Auto-FR | Key/Value pair | This | | | Analytics | containing operational | document. | | | (Global) | state of a Flood | | | | | Reflector Client node. | | +-------+----------------+------------------------------+-----------+ Table 2: Auto-FR Suggested Value(s) for RIFT Well-Known Key-Type Registry Head, et al. Expires 11 January 2024 [Page 13] Internet-Draft RIFT Auto-FR July 2023 8. Security Considerations This document introduces no new security concerns to RIFT or other specifications referenced in this document as RIFT natively secures LIE and TIE packets as described in [RIFT]. 9. Acknowledgements This section will be used to acknowledge major contributors. 10. References 10.1. Normative References [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, DOI 10.17487/RFC2119, March 1997, . [RFC8126] Cotton, M., Leiba, B., and T. Narten, "Guidelines for Writing an IANA Considerations Section in RFCs", June 2017, . [RFC9377] Przygienda, T., Ed., Bowers, C., Lee, Y., Sharma, A., and R. White, "IS-IS Flood Reflection", RFC 9377, DOI 10.17487/RFC9377, April 2023, . [RIFT] Przygienda, T., Sharma, A., Thubert, P., Rijsman, B., Afanasiev, D., and J. Head, "RIFT: Routing in Fat Trees", Work in Progress draft-ietf-rift-rift-18, July 2023, . [RIFT-KV] Head, J. and T. Przygienda, "RIFT Key/Value Structure and Registry", Work in Progress, draft-ietf-rift-kv-registry- 06, July 2023. Appendix A. YANG Model This section serves as a placeholder for a YANG model supporting RIFT Auto-FR. Appendix B. Thrift Models This section contains the normative Thrift models required to support Auto-FR. Per the main RIFT [RIFT] specification, all signed values MUST be interpreted as unsigned values. Head, et al. Expires 11 January 2024 [Page 14] Internet-Draft RIFT Auto-FR July 2023 B.1. common.thrift This section specifies extensions to RIFT common.thrift model. These extensions are REQUIRED in order to support Auto-FR. ... enum AutoFRModel { TunnelMode = 0, NoTunnelMode = 1, } const AutoFRModel default_autofr_model = AutoFRModel.TunnelMode typedef i32 FloodReflectionClusterIDType const FloodReflectionClusterIDType IllegalClusterID = 0 const FloodReflectionClusterIDType DefaultClusterID = 1 /// preference to become FR, higher is better typedef i32 FloodReflectionPreferenceType const FloodReflectionPreferenceType MinFloodReflectionPreference = 0 ... Figure 3: RIFT Auto-FR: common.thrift B.2. encoding.thrift This section specifies extensions to RIFT encoding.thrift model. These extensions are REQUIRED in order to support Auto-FR. Head, et al. Expires 11 January 2024 [Page 15] Internet-Draft RIFT Auto-FR July 2023 struct NodeCapabilities { ... /** indicates whether auto-flood-reflection feature is implemented on this node (but not necessarily enabled). */ 20: optional bool auto_flood_reflection_support = false; ... } struct LIEPacket { ... /** It provides optional version of FR ZTP as 256 * MAJOR + MINOR, indicates support for auto FR */ 40: optional i16 auto_flood_reflection_version; 41: optional common.FloodReflectionClusterIDType auto_flood_reflection_cluster_id; ... } struct NodeTIEElement { ... /** All Auto FR elements MUST be present in at least one TIE in each direction if auto FR is running. */ /** It provides optional version of FR ZTP as 256 * MAJOR + MINOR, indicates support for auto FR */ 30: optional i16 auto_flood_reflection_version; /** cluster ID of Auto FR */ 31: optional common.FloodReflectionClusterIDType auto_flood_reflection_cluster_id; /** preference to become FR */ 32: optional common.FloodReflectionPreferenceType auto_flood_reflection_preference; ... } Figure 4: RIFT Auto-FR: encoding.thrift B.3. common_flood_reflection.thrift This section specifies common_flood_reflection.thrift as a normative THrift model to support core functionality for Auto-FR. These extensions are REQUIRED in order to support Auto-FR. /** Thrift file for common AUTO FLOOD REFLECTION definitions for RIFT Copyright (c) Juniper Networks, Inc., 2016- All rights reserved. */ namespace py common_flood_reflection namespace rs models include "common.thrift" Head, et al. Expires 11 January 2024 [Page 16] Internet-Draft RIFT Auto-FR July 2023 include "encoding.thrift" include "statistics.thrift" typedef binary ISISSystemIDType typedef binary ISISL1NetType struct AutoFRAnyRole { /** common loopback for all nodes */ 1: required common.IPv6Address v6_loopback, /** ISIS L1! loopback in 10.* range, may NOT be collision free due to limited # of bytes */ 2: required common.IPv4Address v4_loopback, 4: required ISISSystemIDType isis_sysid, 5: required ISISL1NetType isis_net, 10: required common.FloodReflectionClusterIDType fr_cluster_id, /** v6 loopback prefix range, used e.g. to clean up config */ 20: required common.IPv6PrefixType v6_loopback_range, /** v6 loopback prefix range of FR reflector loopbacks, used e.g. to clean up config */ 21: required common.IPv6PrefixType fr_loopback_range, /** v6 addresses of all possible FR reflector loopbacks in this config. Can be used for e.g. cleanup */ 24: required set possible_elected_frs, 25: required common.IPv4PrefixType v4_loopback_range, } struct AutoFRReflectorRole { 1: required common.IPv6Address v6_fr_addr_loopback, } struct AutoFRLeafRole { 1: optional i8 empty_placeholder, } struct AutoFRRoles { 1: required AutoFRAnyRole generic, 2: optional AutoFRReflectorRole flood_reflector, 3: optional AutoFRLeafRole leaf, } /// default delay before FR FSM starts to compute anything const common.TimeIntervalInSecType default_autofr_startup_delay = 10 /// default preference to become FR const common.FloodReflectionPreferenceType default_autofr_preference = 0 Figure 5: RIFT Auto-FR: common_flood_reflection.thrift Head, et al. Expires 11 January 2024 [Page 17] Internet-Draft RIFT Auto-FR July 2023 Appendix C. auto_flood_reflection_kv.thrift This section defines auto_flood_reflection_kv.thrift as a method of supporting Auto-FR analytics functionality. Head, et al. Expires 11 January 2024 [Page 18] Internet-Draft RIFT Auto-FR July 2023 include "common.thrift" namespace py auto_flood_reflection_kv namespace rs models typedef i32 AutoFRKeyIdentifier typedef i16 AutoFRCounterType typedef i32 AutoFRLongCounterType const i8 GlobalAutoFRTelemetryKV = 5 /** We don't need the full role structure, only an indication of the node's basic role */ enum AutoFRRole { ILLEGAL = 0, auto_fr_leaf = 1, auto_fr_reflector = 2, auto_fr_spine = 3, // i.e. non-(ToF|Leaf) } /** Auto-FR Global (Node) Telemetry 1st byte MUST be = "Well-Known" 2nd byte MUST be = "GlobalAutoFRTelemetryKV" 3rd/4th bytes MUST be = all 0s Flooding Scope: Leaves only */ struct AutoFRTelemetryGlobalKV { 1: required set auto_fr_roles, 2: required common.FloodReflectionClusterIDType cluster_id, 3: optional AutoFRCounterType established_isis_fr_adjacencies_count, 4: optional AutoFRCounterType total_isis_fr_adjacencies_count, 5: optional AutoFRCounterType established_isis_l1_shortcut_adjacencies_count, 6: optional AutoFRCounterType total_isis_l1_shortcut_adjacencies_count, 7: optional AutoFRCounterType established_isis_l1_adjacencies_count, 8: optional AutoFRCounterType total_isis_l1_adjacencies_count, } Figure 6: RIFT Auto-FR: auto_flood_reflection_kv.thrift Head, et al. Expires 11 January 2024 [Page 19] Internet-Draft RIFT Auto-FR July 2023 Appendix D. Auto-FR Variable Derivation This section contains the normative variable derivation algorithms that are REQUIRED to support Auto-FR. /// indicates how many FRs we're computing in AUTO FR pub const MAX_AUTO_FR_FRS: usize = 3; /// indicates the cluster has no ID, used in computations to omit effects of cluster ID pub const NO_CLUSTER_ID: UnsignedFloodReflectionClusterIDType = 0; /// unique v6 prefix for all nodes starts with this pub fn auto_fr_v6pref(cid: UnsignedFloodReflectionClusterIDType) -> String { format!("FD00:{:04X}:B1", cid) } /// how many bytes in a v6pref for different purposes pub const AUTO_FR_V6PREFLEN: usize = 8 * 5; /// unique v6 prefix for flood reflector purposes starts like this pub fn auto_fr_v6frpref(cid: UnsignedFloodReflectionClusterIDType) -> String { format!("FD00:{:04X}:B2", cid) } /// unique v4 prefix for IRB purposes pub const AUTO_FR_V4LOOPBACKNET: u8 = 10; pub const AUTO_FR_V4LOOPBACKMASK : usize = 8; Figure 7: RIFT Auto-FR: auto_fr_const_structs_types /// auto FR V4 loopback for FRs pub fn auto_fr_cidfrpref2frv4loopback(_cid: UnsignedFloodReflectionClusterIDType, preference: u8) -> Result { if preference > MAX_AUTO_FR_FRS as _ { Err(ServiceErrorType::INTERNALRIFTERROR) } else { let m = ((AUTO_FR_V4LOOPBACKNET as IPv4Address) << (32 - AUTO_FR_V4LOOPBACKMASK)) | (preference as IPv4Address); Ok(m) } } Figure 8: RIFT Auto-FR: auto_fr_cidfrpref2frv4loopback /// auto FR V6 loopback for FRs pub fn auto_fr_cidfrpref2frv6loopback(cid: UnsignedFloodReflectionClusterIDType, preference: u8) -> Result { auto_fr_v6prefixcidsid2loopback(&auto_fr_v6frpref(cid), cid, (1 + preference) as _) } Head, et al. Expires 11 January 2024 [Page 20] Internet-Draft RIFT Auto-FR July 2023 Figure 9: RIFT Auto-FR: auto_fr_cidfrpref2frv6loopback pub fn auto_fr_cidsid2isisnet(cid: UnsignedFloodReflectionClusterIDType, sid: UnsignedSystemID) -> Vec { let mut r = vec![0x49]; // magic AFI // area ID derived from cluster ID r.extend(&cid.to_ne_bytes().iter().fold(0x77u16, |prev, val| (prev ^ (val.rotate_right(4) as u16))).to_ne_bytes()); // ISIS ID derived from system ID + cid/sid r.extend(auto_fr_cidsid2isissid(cid, sid).into_iter()); // selector non v-node r.push(0); r } Figure 10: RIFT Auto-FR: auto_fr_cidsid2isisnet /// ISIS system ID derivation pub fn auto_fr_cidsid2isissid( cid: UnsignedFloodReflectionClusterIDType, sid: UnsignedSystemID) -> Vec { let sb = auto_fr_v6hash(cid, sid); vec![sb[0], sb[1], sb[2], sb[3], sb[4] ^ sb[5].rotate_right(4), sb[6] ^ sb[7].rotate_right(4), ] } Figure 11: RIFT Auto-FR: auto_fr_cidsid2isissid Head, et al. Expires 11 January 2024 [Page 21] Internet-Draft RIFT Auto-FR July 2023 /// v4 loopback address derivation for every node in auto-flood-reflection, returns address pub fn auto_fr_cidsid2v4loopback(cid: UnsignedFloodReflectionClusterIDType, sid: UnsignedSystemID) -> IPv4Address { let mut derived = sid.to_ne_bytes().iter() .fold(0 as IPv4Address, |p, e| (p << 4) ^ (*e as IPv4Address)); derived ^= cid as IPv4Address; // use the byte we loose for entropy derived ^= derived >> (32 - AUTO_FR_V4LOOPBACKMASK); // and sanitize for loopback range, we nuke 8 bits out derived &= (!U32MASKS[AUTO_FR_V4LOOPBACKMASK]) as IPv4Address; let (frpr, frm) = auto_fr_v4frpref(cid); let v4m = U32MASKS[frm as usize]; let mut m = ((AUTO_FR_V4LOOPBACKNET as IPv4Address) << (32 - AUTO_FR_V4LOOPBACKMASK)) | derived; // collision with elected FR v4 prefixes, rederive if (m & v4m as IPv4Address) == frpr { derived ^= IPv4Address::MAX; derived &= (!U32MASKS[AUTO_FR_V4LOOPBACKMASK]) as IPv4Address; m = ((AUTO_FR_V4LOOPBACKNET as IPv4Address) << (32 - AUTO_FR_V4LOOPBACKMASK)) | derived; } m as _ } Figure 12: RIFT Auto-FR: auto_fr_cidsid2v4loopback /// V6 loopback derivation for every node in auto fr pub fn auto_fr_cidsidv6loopback(cid: UnsignedFloodReflectionClusterIDType, sid: UnsignedSystemID) -> Result { auto_fr_v6prefixcidsid2loopback(&auto_fr_v6pref(cid), cid, sid) } Figure 13: RIFT Auto-FR: auto_fr_cidsidv6loopback Head, et al. Expires 11 January 2024 [Page 22] Internet-Draft RIFT Auto-FR July 2023 /// Function sorts vector of systemIDs first, /// Followed by a shuffle taking largest/smallest/2nd largest/2nd smallest. /// Preference is used to take the according subsets to run this algorithm /// sequentially. pub(crate) fn auto_fr_sids2frs(mut v: Vec<(FloodReflectionPreferenceType, UnsignedSystemID)>) -> Vec { v.par_sort_by(|(p1, s1), (p2, s2)| match p2.cmp(p1) { Ordering::Equal => s2.cmp(s1), e @ _ => e }); let mut elected = vec![]; while elected.len() < MAX_AUTO_FR_FRS && !v.is_empty() { let pref = (&v[0]).0; let mut splitat = 0; while splitat < v.len() && (&v[splitat]).0 == pref { splitat += 1; } let mut so = v.split_off(splitat); std::mem::swap(&mut v, &mut so); let mut mixed = if so.len() > 2 { let mut s = so.split_off(so.len() / 2); s.reverse(); interleave(so.into_iter(), s.into_iter()) .collect::>() } else { so }; elected.extend(mixed.drain(..)) } elected.drain(..).map(|(_, sid)| sid).collect() } Figure 14: RIFT Auto-FR: auto_fr_sids2frs pub(crate) fn auto_fr_v62octets(a: Ipv6Addr) -> Vec { a.octets().iter().cloned().collect() } Head, et al. Expires 11 January 2024 [Page 23] Internet-Draft RIFT Auto-FR July 2023 Figure 15: RIFT Auto-FR: auto_fr_v62octets /// generic bytes derivation used for different purposes pub fn auto_fr_v6hash(cid: UnsignedFloodReflectionClusterIDType, sid: UnsignedSystemID) -> [u8; 8] { let sub = (cid as UnsignedSystemID) ^ sid.rotate_right(8); sub.to_ne_bytes() } Figure 16: RIFT Auto-FR: auto_fr_v6hash /// local address with encoded cluster ID and system ID for collision free identifiers. Basis /// for several different prefixes. pub fn auto_fr_v6prefixcidsid2loopback(v6pref: &str, cid: UnsignedFloodReflectionClusterIDType, sid: UnsignedSystemID) -> Result { assert!(cid != ILLEGAL_CLUSTER_I_D as _); let a = format!("{}00::{}", v6pref, sid.to_ne_bytes() .iter() .chunks(2) .into_iter() .map(|chunk| chunk.fold(0u16, |v, n| (v << 8) | *n as u16)) .map(|v| format!("{:04X}", v)) .collect::>() .into_iter() .join(":") ); Ipv6Addr::from_str(&a) .map_err(|_| ServiceErrorType::INTERNALRIFTERROR) } Figure 17: RIFT Auto-FR: auto_fr_v6prefixcidsid2loopback Head, et al. Expires 11 January 2024 [Page 24] Internet-Draft RIFT Auto-FR July 2023 /// cluster prefixes derived instead of advertising default on the cluster to allow /// for default route on ToF or leaves pub fn auto_fr_cid2cluster_prefixes(cid: UnsignedFloodReflectionClusterIDType) -> Result, ServiceErrorType> { vec![ (auto_fr_cidsidv6loopback(cid, ILLEGAL_SYSTEM_I_D as _), AUTO_FR_V6PREFLEN), (auto_fr_cidfrpref2frv6loopback(cid, 0 as _), AUTO_FR_V6PREFLEN), ] .into_iter() .map(|(p, _)| match p { Ok(_) => Ok( IPPrefixType::Ipv6prefix( IPv6PrefixType { address: auto_fr_v62octets(p?), prefixlen: AUTO_FR_V6PREFLEN as _, })), Err(e) => Err(e), } ) .collect::, _>>() } Figure 18: RIFT Auto-FR: auto_fr_cid2cluster_prefixes Authors' Addresses Jordan Head (editor) Juniper Networks 1133 Innovation Way Sunnyvale, CA United States of America Email: jhead@juniper.net Tony Przygienda Juniper Networks 1133 Innovation Way Sunnyvale, CA United States of America Email: prz@juniper.net Colby Barth Juniper Networks 1133 Innovation Way Sunnyvale, CA United States of America Email: cbarth@juniper.net Head, et al. Expires 11 January 2024 [Page 25]